To choose the right air curtain for a door, match the unit’s length to the full width of the opening, then pick a model rated to deliver strong airflow at your door’s mounting height. Next, choose heated or ambient, and match the build to the setting: a shop front, a kitchen or a loading dock. Get those two numbers right, width and height, and most other choices follow.
An air curtain (also called an air door or air curtain machine) is a fan unit mounted above or beside a doorway. It blows a steady sheet of air across the opening. That stream keeps cooled air in and keeps out heat, dust, insects and fumes, while people and goods pass through freely. Below is a step-by-step guide to sizing and selecting one, written from the questions buyers most often ask air curtain manufacturers before they place an order.
What is a commercial air curtain and how does it work?
A commercial air curtain is a wall- or ceiling-mounted fan unit that pushes a high-speed jet of air down across a doorway. The jet forms an invisible barrier between two spaces. Outside air, flying insects and dust can’t easily cross it, and the conditioned air inside stays put.
The key word is jet. The air has to leave the nozzle fast enough to still be moving when it reaches the floor. If it slows down halfway, the barrier breaks and outside air spills in under it. That’s why sizing matters far more than brand or looks.
Why does the right air curtain size matter?
A wrongly sized air curtain machine wastes money in two ways. If it’s too short, air leaks through the uncovered edges of the door. If it’s too weak for the mounting height, the jet fades before the floor, and the door is only half protected.
The right size gives you:
- Lower cooling or heating costs, because conditioned air stays inside
- Fewer flies and mosquitoes, which matters in food and pharma spaces
- Less dust and vehicle fumes at entrances and docks
- A comfortable doorway for staff and customers, without cold or hot drafts
The energy case is well recognised. ASHRAE Standard 90.1, a widely used US energy code for commercial buildings, has allowed certified air curtains in place of an entrance vestibule since its 2019 edition. To qualify, the unit must be tested to ANSI/AMCA 220 and deliver a jet of at least 2 m/s (6.6 ft/s), measured 15 cm above the floor. That’s a useful benchmark even where the code doesn’t apply.
How do I measure my door for an air curtain?
Take three measurements before you speak to any supplier:
- Clear width of the opening, wall to wall, in millimetres or feet.
- Mounting height, from the floor to where the unit will sit. That’s usually just above the door frame, not the door height itself.
- Free space above the door, so the unit, brackets and wiring will fit.
Also note whether the door faces the street or wind, and how often it opens. A door that opens every few seconds, onto a windy road, needs more air than a back-office entrance.
How wide should an air curtain be?
An air curtain should be at least as wide as the door opening. Ideally, it should overlap the frame slightly on both sides. Air curtains are usually sold in fixed lengths, roughly 900 mm (3 ft), 1,200 mm (4 ft), 1,500 mm (5 ft) and 1,800 mm (6 ft). Pick the next size up from your door width.
For wider openings, mount two or more units end to end so the airflow is continuous.
|
Door clear width |
Suggested configuration |
| Up to 0.9 m (3 ft) | One 900 mm unit |
| 0.9 to 1.2 m (3 to 4 ft) | One 1,200 mm unit |
| 1.2 to 1.5 m (4 to 5 ft) | One 1,500 mm unit |
| 1.5 to 1.8 m (5 to 6 ft) | One 1,800 mm unit |
| 1.8 to 2.4 m (6 to 8 ft) | Two 1,200 mm units side by side |
| 2.4 to 3.6 m (8 to 12 ft) | Two 1,800 mm units, or three 1,200 mm units |
What mounting height can an air curtain cover?
Mounting height is the deciding factor when choosing a model. The higher the unit sits, the more velocity it needs at the nozzle to still reach the floor at about 2 m/s. Manufacturers state a maximum recommended mounting height for every model. Treat it as a hard limit, not a target.
| Mounting height | Typical application | Model class to look for |
| Up to about 2.5 m | Shops, clinics, offices, restaurants | Standard commercial air curtain |
| About 2.5 to 3.5 m | Showrooms, malls, hotel and hospital entrances | High-performance commercial |
| About 3.5 to 5 m | Warehouses, cold rooms, service bays | Heavy-duty or industrial |
| Above 5 m | Loading docks, hangars, factory gates | Industrial, often with side-mounted or multiple units |
If your height falls near the top of a model’s range, or the door faces strong wind, go one class higher.
Which type of air curtain machine do I need?
Once size is fixed, choose the type by what you need the air curtain to do:
- Ambient (unheated): the most common type in India. It separates air-conditioned interiors from outside heat, dust and insects. Best for shops, restaurants, clinics and offices.
- Heated (electric or hot-water coil): for cold climates or cold-room anterooms, where staff need warmth at the door.
- Insect-control and food-safe: higher airflow and easy-clean finishes, for kitchens, food processing units and pharma.
- Industrial: larger motors and rugged housings, for warehouses and docks with tall, frequently open doors.
- Recessed or concealed: built into a false ceiling, for premium retail and hotel lobbies where looks matter.
What features should I compare between models?
When comparing quotes from air curtain manufacturers, look beyond price:
- Rated air velocity and air volume (m/s and m³/h), ideally from independent tests such as AMCA 220
- Maximum mounting height for the model
- Motor type and power use, since efficient motors cut running costs
- Noise level (dB), important in shops, hospitals and hotels
- Speed settings and remote or door-switch control
- Body material and finish, for example powder-coated steel or stainless steel for kitchens
- Warranty, spare parts and service support near your site
Where should the air curtain be installed?
Mount the unit on the inside of the door, as close to the top of the opening as possible, with no gap between the nozzle and the frame. Keep it level, and angle the airflow slightly outward if the manufacturer recommends it. Wire it to a door switch so it starts when the door opens. A poorly placed unit that’s correctly sized will still underperform, so follow the installation manual closely.
Quick checklist before you buy
- Door width measured, and unit length covers it fully
- Mounting height within the model’s rated maximum
- Type chosen: ambient, heated, food-safe or industrial
- Power supply and space above the door confirmed
- Door switch or controls included
- Warranty and local service checked
Get the right air curtain for your door
Choosing the right air curtain for a door comes down to two measurements and one decision: width, mounting height and type. Get them right, and you’ll have a comfortable, cleaner doorway with lower energy bills.
Frequently asked questions
1. What size air curtain do I need for my door?
Choose an air curtain at least as long as your door’s clear width, ideally slightly wider. For example, a 1.1 m door needs a 1,200 mm unit. For doors wider than about 1.8 m, mount two units side by side with no gap.
2. Can an air curtain be wider than the door?
Yes, and it’s often better. A unit that overlaps the frame by a few centimetres on each side stops air from slipping in at the edges. A unit narrower than the door leaves gaps and reduces protection.
3. How high can an air curtain be mounted?
It depends on the model. Standard commercial air curtains usually suit openings up to about 2.5 to 3 m. Industrial models cover much taller doors. Always stay within the manufacturer’s rated maximum mounting height for the model you choose.
4. What air velocity should an air curtain deliver?
A good benchmark is about 2 m/s (400 ft/min) near the floor. ASHRAE 90.1 uses this figure, measured 15 cm above the floor, for air curtains that replace a vestibule. Lower velocity at floor level means outside air can leak in.
5. Do air curtains really save energy?
Yes, when sized and installed correctly. They cut the loss of conditioned air through open doors, so the AC or heater works less. Savings depend on door size, how often it opens, wind and the temperature difference inside and out.
6. Does an air curtain keep out flies and mosquitoes?
Yes. A correctly sized air curtain machine with enough velocity creates a barrier most flying insects can’t cross. That’s why they’re common in restaurants, food units and pharma facilities. For insect control, pick a model with higher airflow.
7. Should I choose a heated or an ambient air curtain?
In most Indian cities, an ambient (unheated) commercial air curtain is enough. It keeps cool air in and heat, dust and insects out. Heated models suit cold climates or cold-storage anterooms, where staff need warmth at the door.
8. How do I choose between air curtain manufacturers?
Compare tested air velocity, maximum mounting height, motor efficiency, noise level, build quality, warranty and local service support. Ask for test data, and if you can, a site visit to measure your door. Don’t decide on price alone.